TPR2 Corp. (Thermal Product Research)

161 Interstate Ln.
Waterbury, CT 06705
 
Phone:203-756-TPR2
Fax:203-756-8779
 
fire protection coatings by TPR<sup><small>2</small></sup> Corp. (Thermal Product Research)
request catalogRequest
Catalog
    send email Send Message to
TPR2 Corp. (Thermal Product Research)
   
   
 
Web Site: www.tpr2.com
e-mail: send email
      Specs for fire protection coatings       LEED product data for fire protection coatings      
Overview:
TPR2 is a company developed to provide revolutionary products and solutions for fire, heat, thermal and safety issues that a multiple of industries face today. Our proprietary formulations, unique product compositions and rapid, custom solutions build a strong foundation for cost effective, creative, quick-response solutions to suit our customers' needs.

TPR2’s fire / thermal experience dates back from over 20 years in military and proprietary, private research & development plus countless applications of coatings. Remember, a coating is only as good as the application!

TPR2 understands the importance as well as the cost of the new fire/safety codes being imposed on the marketplace. Although necessary, they do add expense, labor, and almost always, complication. TPR2 coatings, additives, and composites save customers money, unlike the difficulty and expense of making structure modifications in order to comply with new/upgraded codes. Overall system costs actually save customers money.

TPR2 provides custom solutions, quickly, as well as off-the-shelf revolutionary products. TPR2's skilled Solutions Team solves product problems, deals with code adherence issues, addresses special needs/extreme situation requirements and answers application issues.

Products Trade Name Description Content

BUILDING CODE

Green Product Data for

FIRESHELL® - NFPA 286 Thermal Barrier Coating

FIRESHELL®
TPR<sup><small>2</small></sup> Corp. (Thermal Product Research) FIRESHELL® - NFPA 286 Thermal Barrier Coating
click to enlarge
Features
  • Non-flammable, intumescing Coating
  • Expands up to 2000%
  • Provides oxygen starvation
  • Proprietary formulation
  • Non-toxic, drain safe, water based, no fuming
  • Waterbased, 1-Part
  • Interior - White (Can be custom tinted during manufacture)
  • Can be latex or oil base topcoated
Applications
  • Closed cell/open cell sprayfoam, Foam panels, attics, crawlspaces
  • Foam coated piping, boat insulation, ships, barrier foam
Specs for FIRESHELL® - NFPA 286 Thermal Barrier Coating Green Product Data for FIRESHELL® - NFPA 286 Thermal Barrier Coating

FIRESHELL® Interior/Exterior Barrier Coating

FIRESHELL®
TPR<sup><small>2</small></sup> Corp. (Thermal Product Research) FIRESHELL® Interior/Exterior Barrier Coating
click to enlarge
Features
  • Non-flammable, intumescing Coating
  • Expands up to 2000%
  • Provides oxygen starvation
  • Proprietary formulation
  • Non-toxic, drain safe, water based, no fuming
  • Weatherproof
  • Interior / Exterior - Gray
  • Can be latex or oil base topcoat
  • Insulating and fire extinguishing versions available
  • Up to 130 ft2/gallon coverage
Applications
  • Exterior exposed Closed cell/open cell sprayfoam, Foam panels, roof foam
  • Exterior exposed oam coated piping, boat insulation, ships, barrier foam
  • Cabins, barns, foamed attics, lumber, sheathing, siding, roofs
  • Wildland structures, fireproof weather resistant applications, flexible ducts/hoses/pipes
Specs for FIRESHELL® Interior/Exterior Barrier Coating Green Product Data for FIRESHELL® Interior/Exterior Barrier Coating

STRUCTURE SAVIOUR® Fireproof Primer

STRUCTURE SAVIOUR®
TPR<sup><small>2</small></sup> Corp. (Thermal Product Research) STRUCTURE SAVIOUR® Fireproof Primer
click to enlarge
THIS NEW REVOLUTIONARY COATING
  • Has passed Urban / Wildland Code requirements that render siding, lumber, sheathing and walls Non combustible to fire.
  • Pass IBC's ignition barrier and E-119 thermal fire ratings on walls, lumber, and siding.
  • Exceeds ASTM test requirements for use as weather and water resistant coatings.
  • Is fire extinguishing to handle convection, radiant and firebrands!
  • Can be made red or brown for barns, timber homes and roofs.
Applications
  • Interior/exterior walls, lumber, roofs, siding, sheathing
  • Siding, fencing, wildland buildings
Specs for STRUCTURE SAVIOUR® Fireproof Primer Green Product Data for STRUCTURE SAVIOUR® Fireproof Primer

Non-Flammable Exterior Paint

TPR<sup><small>2</small></sup> Corp. (Thermal Product Research) Non-Flammable Exterior Paint
click to enlarge
Features
  • White, Non-flammable Coating
  • Highly Ductile...elastomeric like
  • Proprietary formulation
  • Non-toxic, drain safe, water based, no fuming
  • Interior / Exterior - White, tintable**
  • Topcoatable
  • Can be made insulative/high heat
  • Sprayable
  • Up to 150 ft2/gallon coverage
Applications
  • Exterior walls, lumber, roofs, siding, sheathing
  • Siding, fencing, barns, wildland buildings
Specs for Non-Flammable Exterior Paint Green Product Data for Non-Flammable Exterior Paint

FIRESAFE® Interior Paint

FIRESAFE®
TPR<sup><small>2</small></sup> Corp. (Thermal Product Research) FIRESAFE® Interior Paint
click to enlarge
Features
  • White, Non-flammable Coating
  • AQMD Super Compliant
  • Proprietary formulation
  • Non-toxic, drain safe, water based, no fuming
  • Interior - tintable
  • Topcoatable
  • Sprayable
  • Up to 200 ft2/gallon coverage
Applications
  • Electrical panels, walls, gypsum, plastics
Specs for FIRESAFE® Interior Paint Green Product Data for FIRESAFE® Interior Paint

HEATSHEDDER® Interior Primer

HEATSHEDDER®
TPR<sup><small>2</small></sup> Corp. (Thermal Product Research) HEATSHEDDER® Interior Primer
click to enlarge
Features
  • White, Non-flammable Coating
  • AQMD Super Compliant
  • Hardshell™ barrier coating maintains integrity
  • Provides oxygen starvation
  • Can be made fire extinguishing
  • Non-toxic, drain safe, water based, no fuming
  • Sprayable
  • Interior - tintable
  • Topcoatable
  • Sprayable
  • Up to 125 ft2/gallon coverage
Applications
  • Electrical panels, walls, gypsum, plastics
Specs for HEATSHEDDER® Interior Primer Green Product Data for HEATSHEDDER® Interior Primer

URBAN / WILDLAND CODE

Green Product Data for

AFES Fire Extinguishing Coating

AFES
TPR<sup><small>2</small></sup> Corp. (Thermal Product Research) AFES Fire Extinguishing Coating
click to enlarge
Features
  • Non-flammable Coating
  • Extinguishes liquid fires
  • Vapor fires - maintains integrity
  • Proprietary formulation
  • Non-toxic, drain safe, water based, no fuming
  • Interior / Exterior - tintable
  • Can be made insulative / high heat
  • Sprayable
  • Up to 110 ft2/gallon coverage
Applications
  • Walls, foam, attics, lumber, sheathing, siding, roofs
  • Oil rigs, piping, boats, ships, race cars, hoses, electrical assemblies
  • Construction equipment, transformers, Mining, Industrial vehicles
Specs for AFES Fire Extinguishing Coating Green Product Data for AFES Fire Extinguishing Coating

FIRESHELL® Mastic

FIRESHELL®
TPR<sup><small>2</small></sup> Corp. (Thermal Product Research) FIRESHELL® Mastic
click to enlarge
Features
  • Non-flammable, reinforced, intumescing Coating
  • Expands up to 2000%
  • Provides oxygen starvation
  • Proprietary formulation
  • Non-toxic, drain safe, water based, no fuming
  • Interior / Exterior - Gray
  • Can be latex or oil base topcoat
  • Insulating and fire extinguishing versions available
  • Funnel sprayable
Applications
  • Steel columns, mining
Specs for FIRESHELL® Mastic Green Product Data for FIRESHELL® Mastic


spacer