1. Configure The Quikrete Companies MASONRY MORTAR:
APPLICATIONS
Foundations:
SELECT MORTAR TYPE
----------
Use Type M
Use Type S
Other Masonry:
SELECT MORTAR TYPE
----------
Use Type M
Use Type S
Use Type N
CEMENT/LIME MORTAR
Type M Mortar
Compressive Strength: 2500 psi (17.2 MPa), minimum
Water Retention: 75 percent, maximum
Air Content: 12 percent, maximum
Type S Mortar
Compressive Strength: 1800 psi (12.4 MPa), minimum
Water Retention: 75 percent, maximum
Air Content: 12 percent, maximum
Type N Mortar
Compressive Strength: 750 psi (5.2 MPa), minimum
Water Retention: 75 percent, maximum
Air Content: 14 percent, maximum; maximum 12 percent when structural reinforcement is incorporated into mortar
Masonry Mortar Mix: Factory blended hydraulic cement/lime/sand mix
MASONRY CEMENT MORTAR
Type M Mortar
Compressive Strength: 2500 psi (17.2 MPa), minimum
Water Retention: 75 percent, maximum
Air Content: 18 percent, maximum
Type S Mortar
Compressive Strength: 1800 psi (12.4 MPa), minimum
Water Retention: 75 percent, maximum
Air Content: 18 percent, maximum
Type N Mortar
Compressive Strength: 750 psi (5.2 MPa), minimum
Water Retention: 75 percent, maximum
Air Content: 20 percent, maximum; maximum 18 percent when structural reinforcement is incorporated into mortar
Masonry Mortar Mix: Factory blended masonry cement/sand mix
Masonry Cement:
SELECT MASONRY CEMENT
----------
Type M
Type S
Type N
ACCESSORY MATERIALS
Water: Clean and free from deleterious acids, alkalies, and organic matter
Admixtures: Complying with ASTM 1384 or ICBO-ES Evaluation Report 3759
Pigment:__________
Integral Waterproofer:__________