1. Configure Steel Door Institute - STEEL DOORS AND FRAMES:
Frames
Interior Frames:
Level 1 Standard Duty-Use With: 
Level 2 Heavy Duty-Use With: 
Level 3 Extra Heavy-Duty-Use With: 
Exterior Frames:
Level 1 Standard Duty-Use With: 
Level 2 Heavy Duty-Use With: 
Level 3 Extra Heavy-Duty-Use With: 
Level 4 Maximum-Duty-Use With: 
Note: If Galvanized Frames are Required, Select One of the Two Following Methods of Indication for Location
Provide units of galvanized steel where indicated on the door schedule
Provide units of galvanized steel in the following locations
Exterior openings, as noted on door schedule
Kitchens, as noted on door schedule
Toilets, as noted on door schedule
Washrooms, as noted on door schedule
Locker rooms, as noted on door schedule
Showers, as noted on door schedule
Laboratories, as noted on door schedule
Frame Construction: 
Slip-on drywall frame anchors shall be as provided by the manufacturer to assure performance specified
Borrowed or Sidelights Required - Provide glazing stops and beads where glazed lights are indicated
Doors
Interior Doors:
Level 1 - Standard Duty 1-3/8 inches (34.9 mm): 
Level 1 - Standard Duty 1-3/4 inches (44.5 mm): 
Level 2 - Heavy Duty 1-3/4 inches (44.5 mm): 
Level 3 - Extra Heavy-Duty 1-3/4 inches (44.5 mm): 
Level 4 - Maximum-Duty 1-3/4 inches (44.5 mm): 
Exterior Doors:
Level 1 - Standard Duty 1-3/8 inches (34.9 mm): 
Level 1 - Standard Duty 1-3/4 inches (44.5 mm): 
Level 2 - Heavy Duty 1-3/4 inches (44.5 mm): 
Level 3 - Extra Heavy-Duty 1-3/4 inches (44.5 mm): 
Level 4 - Maximum-Duty 1-3/4 inches (44.5 mm): 
Decorative Door Faces: Provide textured or embossed steel faces as indicated
Face steel sheet shall meet at least one or more of the following requirements:
Level 1: 
Level 2: 
Level 3: 
Level 4: 
End Closure: 
Provide louvers and vision lites where indicated on the Drawings in accordance with ANSI/SDI A250.8
Provide steel astragals where indicated on the Drawings or where required by the manufacturer or NFPA 80
Fabrication
Factory Applied Finish: Meet performance requirements & acceptance criteria as stated in ANSI/SDI A250.3.
Color shall be: 
Design Clearances: Fabricate doors and frames to maintain the following clearances
Clearance at the Bottom: 
Quality Assurance
Fire Rated Doors & Frames: Ratings as indicated on Door Schedule, when tested in accordance
with NFPA 252, UL 10B or UL 10C
Stairwell Doors: 250 deg F (121 deg C) or 450 deg F (232 deg C) temp rise rating
as well as the required fire rating
 2. When you are finished making selections:
  Generate Spec: Word     WP   or   RTF